Figure 9-3
Representation of the bit states of the prelimit/limit switches on the display screen "Status of the
drives [3]"
Table 9-1
1+/1+
1+
0
1-
1-/1-
2
0/2
2/2
9.3.7

Setting up FTP file access

With SIMOTION firmware V4.4 and higher, a user name and password must be stored on the
CF card for the use of FTP, web services or access-protected pages. If this has already been
set up, you can skip the next step and continue with "Setting user name and password in
SIMOCRANE CeCOMM".
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Monitor function, "Status of drives" [3] display screen
Explanation of display screen [3]
Prelimit switch forward and limit switch forward responded
Prelimit switch forward responded
No limit switch responded
Prelimit switch backward responded
Prelimit switch backward and limit switch backward responded
Prelimit switch forward and prelimit switch backward responded
Limit switch forward and limit switch backward responded
All limit switches responded
Commissioning AddOn Software
9.3 Commissioning requirements for AddOn software