Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 429

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

P306 Factor pendulum length for 30 ft container
Factor for calculating the effective pendulum length for a 30-foot long spreader
Default: -1
Access code: 0
P307 Offset pendulum length for 30 ft container
Offset for calculating the effective pendulum length for a 30-foot long spreader
Default: 50000
Access code: 0
P308 Factor pendulum length for 40 ft container
Factor for calculating the effective pendulum length for a 40-foot long spreader
Default: -1
Access code: 0
P309 Offset pendulum length for 40 ft container
Offset for calculating the effective pendulum length for a 40-foot long spreader
Default: 50000
Access code: 0
P310 Factor pendulum length for 45 ft container
Factor for calculating the effective pendulum length for a 45-foot long spreader
Default: -1
Access code: 0
P311 Offset pendulum length for 45 ft container
Offset for calculating the effective pendulum length for a 45-foot long spreader
Default: 50000
Access code: 0
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
min: -100000
min: -300000
min: -100000
min: -300000
min: -100000
min: -300000
max: 100000
max: 300000
max: 100000
max: 300000
max: 100000
max: 300000