2-10. Wired remote controller (UTY-RNKU)

DIP switch 1
DIP switch 2
¢ Switch location
¢ DIP switch 1 setting
• SW1: Setting prohibited
• SW2: Dual remote controller setting
Set the remote controller SW2 according to the following table.
Number of remote controller
1 (Normal)
2 (Dual)
2-10. Wired remote controller (UTY-RNKU)
SW1
Prohibited
SW2
Dual remote controller setting
SW3
Prohibited
SW4
Fahrenheit (°F)/Celsius (°C) setting
SW5
Prohibited
SW6
Memory backup setting (Only for wired remote controller)
Do not use. (All switches fixed at OFF.)
Front case (back side)
DIP Switch 2
(All switches
SW1
OFF
ON
Primary unit
SW2
When ground wire
is necessary
OFF
1
2
3
4
5
6
ON
DIP Switch 1
Fixed at OFF
Setting prohibited
Secondary unit
SW2
OFF
OFF
ON
Indoor unit
Remote controller cable
1 2 3
1 2 3
1 2 3
Master unit
Slave unit
Remote controller
- (07-101) -
ON
Factory setting
Factory setting