Setting Maximum Speed And Robot Acceleration/Deceleration For Load Conditions - Toshiba TH850A Instruction Manual

Industrial robot
Hide thumbs Also See for TH850A:
Table of Contents

Advertisement

DELAY 1
PAYLOAD={3,30}
MOVE P2+POINT(0,0,100)
GOTO LOOP
FIN:
MOVE P0
DOUT(1)
STOP
END
c)
Setting of PAYLOAD command
In the default state, or when the PAYLOAD command is not used, the maximum
speed and acceleration/deceleration are set to 100 % and the servo gain is set to
the value under the minimum load. (See Para. 5.3.3.)
Be sure to use the PAYLOAD command.
Unless the PAYLOAD command is used, the robot will vibrate or overshoot,
resulting in malfunction or shortening of the life of the mechanisms. In the
worst case, the mechanism will be damaged.
Even when the PAYLOAD command is used, regulate the speed by using the
SPEED or DECEL command while confirming the workpiece behavior
subject to handling.
The load moment of inertia should be within the tolerances given in Table
5.1.
Even if there is no offset of load gravity center, if the moment of inertia is
large, the robot may vibrate. When this happens, figure out the virtual
gravity center offset (L mm) from the following equation, using the moment of
inertia (J kg·m
(J × 10
L =
Then, designate the following command.
PAYLOAD = {M, L}
TRANSPORTATION AND INSTALLATION MANUAL
!
!
2
) and mass (M kg).
6
/ M)
– 71 –
CAUTION
CAUTION
STE80753

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th1050aTh1200a

Table of Contents