LG SV-iC5 Series Instruction Manual page 116

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

11. Monitoring
2 : FDT-3
It activates when run frequency meets the following condition.
Active condition: Absolute value (FDT level - run frequency) <= FDT Bandwidth/2
Group
LED Display
I/O group
It cannot be set above F21- [Max frequency].
When setting I52 and I53 to 30.0Hz and 10.0 Hz, respectively
3 : FDT-4
Become active when run frequency meets the following condition.
Active condition
LED
Group
Display
I/O group
I52
I53
Cannot be set above F21- [Max Frequency].
When setting I52, I53 to 30.0 Hz and 10.0Hz, respectively.
Parameter Name
[Frequency
I52
level]
[Frequency
I53
Bandwidth]
30Hz
Freq.
MO
Run
command
Accel time: Run Frequency >= FDT Level
Decel time: Run Frequency > (FDT Level – FDT Bandwidth/2)
Description
[Frequency Detection level]
[Frequency
Bandwidth]
30Hz
Freq.
MO
Run
command
Set
value
Detection
-
Detection
-
Set
value
-
Detection
-
11-8
Min/Max
Factory
range
default
30.0
0/400
10.0
35Hz
25Hz
Min/Max
Factory
range
default
30.0
0/400
10.0
25Hz
SV-iC5
Unit
Hz
Unit
Hz

Hide quick links: