5. Programming keypad
How to monitor fault condition in Drive group
Drive group
1
2
3
4
5
When more than one fault occur at the same time,
Drive group
Over-
current
trip
-. This message appears when an Overcurrent fault occurs.
-. Press the Prog/Ent ( ) key once.
-. The run frequency at the time of fault (30.0) is displayed.
-. Press the Up ( ) key once.
-. The output current at the time of fault is displayed.
-. Press the Up ( ) key once.
-. Operating status is displayed. A fault occurred during acceleration.
-. Press the STOP/RST key once.
-. A fault condition is cleared and "nOn" is displayed.
Motor
overheating
Over
voltage
Over
current
STOP/RST
-. Maximum three faults information is displayed as
shown left.
5-12