LG SV-iC5 Series Instruction Manual page 58

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

7. Function list
LED
Parameter
display
name
I 0
[Jump code]
I 1
[Filter time
constant for
V0 input]
I 2
[V0 input Min
voltage]
I 3
[Frequency
corresponding
to I 2 ]
I 4
[V0 input Max
voltage]
I 5
[Frequency
corresponding
to I 4]
I 6
[Filter time
constant for
V1 input]
I 7
[V1 input Min
voltage]
I 8
[Frequency
corresponding
to I 7]
I 9
[V1 input max
voltage]
I10
[Frequency
corresponding
to I 9]
I11
[Filter time
constant for I
input]
I12
[I input
minimum
current]
Min/Max
range
0/63
This parameter sets the code number to jump
0/9999
This is used to adjust the analog voltage input
signal via keypad potentiometer.
0/10
Set the minimum voltage of the V0 input.
[V]
0/400
Set the inverter output minimum frequency at
[Hz]
minimum voltage of the V0 input.
0/10
Set the maximum voltage of the V0 input.
[V]
0/400
Set the inverter output maximum frequency at
[Hz]
maximum voltage of the V0 input.
0/9999
Set the input section's internal filter constant for
V1 input.
0/10
Set the minimum voltage of the V1 input.
[V]
0/400
Set the inverter output minimum frequency at
[Hz]
minimum voltage of the V1 input.
0/10
Set the maximum voltage of the V1 input.
[V]
0/400
Set the inverter output maximum frequency at
[Hz]
maximum voltage of the V1 input.
0/9999
Set the input section's internal filter constant for
I input.
0/20
Set the Minimum Current of I input.
[mA]
Description
7-16
I/O group
Factory
Adjustable
defaults
during run
1
O
10
O
0
O
0.0
O
10
O
60.0
O
10
O
0
O
0.0
O
10
O
60.0
O
10
O
4
O
SV-iC5
Page
5-5
9-2
9-3
9-4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents