9.3

Run Command setting

Run via the Run and STOP/RST key
Group
LED Display
Drive
drv
group
drC
Set drv – [Drive mode] to 0.
Motor starts to accelerate by pressing the Run key while run frequency is set. Motor decelerates to stop by
pressing the STOP/RST key.
Selecting rotation direction is available at drC - [Direction of motor rotation select] when run command is
issued via Run key on keypad.
FX : Counter clockwise
Run command setting 1 via FX and RX terminals
Group
LED Display
Drive
drv
group
I/O group
I20
I21
Set drv – [Drive mode] to 1.
Set I20 and I21 to 0 and 1 to use P1 and P2 as FX and RX terminals.
"FX" is Forward run command and "RX" Reverse run.
Operation will stop when both FX and RX terminals are turned ON or OFF.
Frequency
FX
RX
Parameter Name
[Drive mode]
(Run/Stop mode)
[Direction of motor rotation
select]
drC
Parameter Name
[Drive mode]
(Run/Stop mode)
[Multi-function input terminal
P1 define]
[Multi-function input terminal
P2 define]
9-7
Set
Min/Max
Value
Range
0
0/3
-
F/r
[Direction of motor
F
rotation select]
R
Set
Min/Max
Value
Range
1
0/3
0
0/24
1
0/24
9. Basic functions
Factory
Unit
Defaults
1
F
Forward
Reverse
Factory
Unit
Defaults
1
0
1