9. Basic functions
Analog Frequency setting via Potentiometer (V0) on the Keypad
Used to prevent fluctuations in analog input signals caused by noise
Group
LED Display
Drive
0.0
group
Frq
I/O group
I 1
I 2
I 3
I 4
I 5
Set Frq – [Frequency Mode] to 2.
The set frequency can be monitored in 0.0- [Frequency Command].
I 1 : [Filtering time constant for V0 input]
Effective for eliminating noise in the frequency setting circuit.
Increase the filter time constant if steady operation cannot be performed due to noise. A larger setting
results in slower response (t gets longer).
I 2 - I 5 : [Min/Max input voltage and corresponding frequency setting]
The corresponding frequency to V0 input voltage is settable.
Example: When setting I 2 - [V0 input minimum voltage] = 2V, I 3- [Frequency corresponding to I 2]=
10Hz, I 4 - [V0 input max voltage] = 8V and I 5 - [Frequency corresponding to I 4]= 50Hz, the following
figure is shown.
Parameter Name
[Frequency Command]
[Frequency Mode]
[Filter time constant for V0 input]
[V0 input minimum voltage]
[Frequency corresponding to I2]
[V0 input max voltage]
[Frequency corresponding to I4]
V0 input
Set freq
t
Freq.
setting
50Hz
I 5
10Hz
I 3
2V
I 2
Set
Min/Max
Value
Range
-
2
10
0/9999
-
-
0/400
-
-
0/400
8V
V0 input
I 4
9-2
Factory
Defaults
-
-
0/8
0
10
0/10
0
0.0
0/10
10
60.0
SV-iC5
Unit
Hz
V
Hz
V
Hz