Glow Plug and Lower Reels Timer (GR 3200–D)
This is a solid state timer. Upon the application of power,
the load is energized and the time delay is started. After
6 seconds the load is de–energized.
1. Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After 6 seconds, there should
be no voltage across the load.
2. Disconnect timer from 12VDC source and test load.
Figure 37
Glow Relay (GR 3200–D)
1. Verify coil resistance between terminals 86 and 85
with a multimeter (ohms setting). Resistance should be
from 41 to 51 ohms.
2. Connect multimeter (ohms setting) leads to relay
terminals 30 and 87. Ground terminal 86 and apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as 12 VDC is ap-
plied and removed from terminal 85.
3. Disconnect voltage from and multimeter leads from
relay terminals.
Electrical System
TIMING
RESISTOR
86
85
Page 6 – 38
+
INPUT VOLTAGE
LOAD
3
2
1
4
5
Figure 38
Figure 39
87
87
30
85
86
Figure 40