High Temperature Switch (GR 3200–D)
The switch is located on top of the water pump. The
pump is between the fan pulley assembly and the cylin-
der head. There is a blue wire attached to the switch
(Fig. 32).
1. Lower the coolant level in the engine and remove
the high temperature shutdown switch.
2. Put the switch in a container of oil with a thermome-
ter and slowly heat the oil (Fig. 33).
CAUTION
Handle the hot oil with extreme care to pre-
vent personal injury or fire.
3. Check the continuity of the switch with a multimeter
(ohms setting). The switch is normally open and should
close at 206 to 218 F (97 to 103 C)
4. Allow the oil to cool. The switch should open at
194 F (90 C).. Replace switch as necessary.
5. Install switch and restore coolant level to the engine.
Greensmaster 3200/3200–D
1. High temperature shutdown switch
Page 6 – 35
Figure 32
Figure 33