Inspecting Reservoir Parts (Fig. 85)
1. Clean tank and filler screen with solvent.
2. Inspect tank for leaks, cracks, or other damage.
3. Replace hydraulic hoses if worn or leaking.
4. Make sure cap screws are secure. If loose, remove
and reinstall cap screws with "Loctite 242" or equivalent.
5. Make sure all bracket fasteners are tight.
Installing Hydraulic Reservoir (Fig. 85)
1. If removed from the hydraulic tank (6), install the fol-
lowing:
A. O–ring (27), hydraulic barb fitting (1), and pump
inlet hose (31).
B. O–ring (25), hydraulic fitting (2), and hose as-
sembly (32).
C. O–ring (29) and hydraulic barb fitting (9).
Hydraulic System
2. Place antiseize lubricant into all four inserts at the
bottom of the hydraulic tank (6). Position tank onto the
mounting plate (11).
3. Secure hydraulic tank to the mounting plate with
four cap screws (16) and flat washers (12). Torque cap
screws from 30 to 60 in–lb (35 to 69 kg–cm).
4. Secure mounting plate (11) to the frame with three
hex head screws and flat washers Two screws go on the
top of the plate at the front corners of the fuel tank. The
third screw goes in front of the castor fork and below the
plate.
5. Secure console shroud to the hydraulic tank with
cap screw and flat washer, and to the lower panel with
both cap screws and flat washers (Fig. 88).
6. Secure formed hose (21) to hydraulic barb fitting (9)
with hose clamp (23).
7. Connect hose assembly to the hydraulic fitting
welded to the reel motor case drain tube located below
the right side of the frame (Fig. 87).
8. Secure pump inlet hose to hydrostat with hose
clamp (Fig. 86).