NAP- 200-007
Sheet 4/42
Termination of Cables on MDF
(3)
Figure 007-3 shows the LTC Connector Pin Arrangement.
(a)
PIM0 (LTC0 ~ LTC2)
LTC0
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
MN
LTC2
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
LEN0000
2
0001
LT00
3
0002
4
0003
5
0004
6
0005
LT01
7
0006
8
0007
9
0008
10
0009
LT02
11
0010
12
0011
13
0012
14
0013
LT03
15
0014
16
0015
17
0016
18
0017
LT04
19
0018
20
0019
21
0020
22
0021
LT05
23
0022
24
LEN0023
25
MJ
1
LEN0048
2
0049
LT12/AP2
3
0050
4
0051
5
0052
6
0053
LT13/AP3
7
0054
8
0055
9
0056
10
0057
LT14/AP4
11
0058
12
0059
13
0060
14
0061
LT15/AP5
15
0062
16
LEN0063
17
AP6
18
19
20
21
22
23
24
25
Figure 007-3: LTC Connector Pin Arrangement
LTC1
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Note: These pins are used only for
the PN-BRTA and PN-30DTC.
AD-25182501
1
2
LEN0024
3
0025
LT06
4
0026
5
0027
6
0028
7
0029
LT07
8
0030
9
0031
10
0032
11
0033
LT08
12
0034
13
0035
14
0036
15
0037
LT09
16
0038
17
0039
18
0040
19
0041
LT10/AP0
20
0042
21
0043
22
0044
23
0045
LT11/AP1
24
0046
25
LEN0047