NEC NEAX 7400 ICS Installation Manual page 108

Table of Contents

Advertisement

NAP- 200-007
Sheet 31/42
Termination of Cables on MDF
(9) Paging Equipment
The cross connection for customer-owned paging equipment is shown in Figure 007-18 and Figure 007-19,
as an example.
Requirement for the Paging Equipment
• Input Impedance : 600 ohm
• Control Method : Start - Ground ON
(a)
Outline of the Connection
PN-DK00 Card
PN-4COT/2COT Card
PZ-PW86 Card
-27V
Figure 007-18 Outline of the Paging Equipment Connection
CHAPTER 3
Page 94
Revision 1.0.1
: Stop - Ground Off (Open)
PABX
}
Refer to the Command Manual to set
the PN-DK00 in the Relay-Drive Mode.
MDF
A U S T E L - a p p r o v e d
L i n e I s o l a t i o n U n i t
AD-25182501
F o r A m p l i f i e r I n p u t
P a g i n g E q u i p m e n t
F o r C o n t r o l ( O p t i o n a l )