NEC NEAX 7400 ICS Installation Manual page 107

Table of Contents

Advertisement

NAP- 200-007
Sheet 30/42
Termination of Cables on MDF
(c)
MDF Cross Connection
• When using a TAS Indicator without a Battery
Note: Refer to the Command Manual to set the PN-DK00 in the Relay-Drive mode.
PN-DK00
LEN0000
LT00
LEN0002
PZ-PW86
-27V
GND
Figure 007-17 MDF Cross Connection for a TAS Indicator without a Battery
PIM0
K0
K1
K2
K3
K4
K5
K6
K7
LTC0 (J)
26
K1
1
LEN0000
27
K3
2
28
K5
3
LEN0002
29
K7
4
LTC0
J
P
1
1
26
26
2
2
27
27
3
3
28
28
4
4
29
29
(P)
K0
1
K0
26
K2
2
K2
27
K4
3
K4
28
K6
4
K6
29
AD-25182501
TAS INDICATOR
MDF
WITHOUT BATTERY
K0
IND
(24V. nom.)
K1
K3
K5
K7
CHAPTER 3
Page 93
Revision 1.0.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

120

Table of Contents