Func.
N a m e
Code
d023
Program counter monitor
[EzSQ]
Program number monitor
d024
[EzSQ]
User monitor 0
d025
[EzSQ]
d026
User monitor 1
[EzSQ]
User monitor 2
d027
[EzSQ]
d029
Positioning command monitor
Current position monitor
d030
d050
Dual monitor
d060
Inverter mode monitor
d062
Frequency source monitor
d063
Run command source monitor
Trip counter
d080
Trip monitor 1
d081
d082
Trip monitor 2
d083
Trip monitor 3
Trip monitor 4
d084
d085
Trip monitor 5
Trip monitor 6
d086
Warning monitor
d090
d102
DC bus voltage monitor
BRD load ratio monitor
d103
d104
Electronic thermal monitor
d130 
Analog input O monitor
" d " F u n c t i o n
D e s c r i p t i o n
Range is 0 to 1024
Range is 0 to 9999
Result of EzSQ execution, range is
–2147483647~2147483647
Result of EzSQ execution, range is
–2147483647~2147483647
Result of EzSQ execution, range is
–2147483647~2147483647
Displays the positioning command,
range is –268435455~+268435455
Displays the current position, range
is –268435455~+268435455
Displays two different data
configured in b160 and b161.
Displays currently selected inverter
mode :
I-C:IM CT mode/I-V:IM VT mode/
P:PM mode
0...Operator
1-15...1-15 Multi-speed
16...Jog frequency
18...Modbus communication
19...Option
21...Potentiometer(available with
OPE-SR or OPE-SRmini)
22...Pulse train
23... Calculate function output
24...EzSQ / 25... [O] input
26... [OI] input / 27... [O] + [OI] input
1...Control terminal / 2...Operator
3...Modbus network / 4...Option
Number of trip events,
Range is 0. to 9999. (0 to 9999) /
1000 to 6553 (10000 to 65530)
Displays trip event information:
Error code
Output frequency at trip point
Motor current at trip point
DC bus voltage at trip point
Cumulative inverter operation
time at trip point
Cumulative power-ON time at
trip point
Displays the warning code
Voltage of inverter internal DC bus,
Range is 0.0 to 999.9 / 1000.
Usage ratio of integrated brake
chopper, range is 0.0~100.0%
Accumulated value of electronic
thermal detection, range is from
0.0~100.0%
0 to 1023
48
Run
Mode
Units
Edit
events
V
%
%