F u n c .
N a m e
C o d e
A012
[O] input active range end
frequency
[O] input active range start
A013
voltage
A014
[O] input active range end
voltage
A015
[O] input start frequency
enable
A016
Analog input filter
A017
EzSQ select
Multi-speed operation
A019
selection
A020
Multi-speed freq. 0
Multi-speed freq. 0,
A220
nd
2
motor
A021
Multi-speed freq. 1 to 15
(for both motors)
to
A035
A038
Jog frequency
A039
Jog stop mode
" A" F u n c t i o n
D e s c r i p t i o n
The output frequency
corresponding to the analog
input range ending point,
range is 0.0 to 400.0
The starting point (offset) for the
active analog input range,
range is 0. to A014 value (%)
The ending point (offset) for the
active analog input range,
range is A013 value to 100.(%)
Two options; select codes:
00Use offset (A011 value)
01Use 0Hz
Range n = 1 to 31,
1 to 30 : ×2ms filter
31: 500ms fixed filter with ±
0.1Hz hys.
00...Disable
01...PRG terminal
02...Always
Select codes:
00...Binary operation (16 speeds
selectable with 4 terminals)
01...Bit operation (8 speeds
selectable with 7 terminals)
Defines the first speed of a
multi-speed profile,
range is 0.0 / start frequency to
400Hz
A020 = Speed 0 (1st motor)
Defines the first speed of a
multi-speed profile or a 2nd
motor, range is 0.0 / start
frequency to 400Hz
A220 = Speed 0 (2nd motor)
Defines 15 more speeds,
range is 0.0 / start frequency
to 400 Hz.
A021=Speed 1 ~ A035=Speed15
A021 ~ A035
Defines limited speed for jog,
range is from start frequency to
9.99 Hz
Define how end of jog stops the
motor; six options:
00Free-run stop
(invalid during run)
01Controlled deceleration
(invalid during run)
02DC braking to stop
(invalid during run)
03Free-run stop
(valid during run)
04Controlled deceleration
(valid during run)
05DC braking to stop
(valid during run)
52
D e f a u l ts
Run
Mode
I n i t i a l
U n i ts
Edit
d a ta
*
1
0.00
*
0.
1
*
100.
1
*
1
01
*
8.
Spl.
1
00
00
0.0
0.0
See next
row
0.0
6.00
*
1
04
Hz
%
%
Hz
Hz
Hz
Hz
Hz