F u n c .
N a m e
C o d e
b085
Country for initialization
Frequency scaling conversion
b086
factor
STOP key enable
b087
b088
Restart mode after FRS
b089
Automatic carrier frequency
reduction
Dynamic braking usage ratio
b090
b091
Stop mode selection
Cooling fan control
b092
b093
Clear elapsed time of cooling
fan
b094
Initialization target data
" b " F u n c t i o n
D e s c r i p t i o n
Select default parameter values for
country on initialization, two option
codes:
00area A
Specify a constant to scale the
displayed frequency for d007
monitor, range is 0.01 to 99.99
Select whether the STOP key on the
keypad is enabled, three option
codes:
00Enabled
01Disabled always
02Enabled only for trip reset
Selects how the inverter resumes
operation when free-run stop (FRS)
is cancelled, three options:
00Restart from 0Hz
01Restart from frequency
detected from real speed of
motor (freq. matching)
02Restart from frequency
detected from real speed of
motor (active freq. matching)
Three option codes:
00Disabled
01Enabled, depending on the
output current
02Enabled, depending on the
heat-sink temperature
Selects the rate of use (in %) of the
regenerative braking resistor per
100 sec. intervals, range is 0.0 to
100%.
0%: Function disabled
>0%: Enabled, per value
Select how the inverter stops the
motor, two option codes:
00DEC (decelerate to stop)
01FRS (free-run to stop)
Selects when the fan is ON during
inverter operation, three options:
00Fan is always ON
01Fan is ON during run, OFF
during stop (5 minute delay
from ON to OFF)
02Fan is temperature controlled
Two option codes:
00Count
01Clear
Select initialized parameters, four option
codes:
00All parameters
01All parameters except in/output
terminals and communication.
02Only registered parameters in Uxxx.
03All parameters except registered
parameters in Uxxx and b037.
64
Run
Mode
Edit
01area B
*
1
*
1
*
1
*
1
*
1
D e f a u l ts
I n i t i a l
U n i ts
d a ta
00
1.00
00
00
01
-
0.0
%
00
01
00
00