F u n c .
N a m e
C o d e
b050
Controlled deceleration on
power loss
DC bus voltage trigger level of
b051
ctrl. decel.
Over-voltage threshold of ctrl.
b052
decel.
b053
Deceleration time of ctrl. decel.
b054
Initial freq. drop of ctrl. decel.
Maximum-limit level of window
b060
comparator (O)
b061
Minimum-limit level of window
comparator (O)
Hysteresis width of window
b062
comparator (O)
b063
Maximum-limit level of window
comparator (OI)
Minimum-limit level of window
b064
comparator (OI)
b065
Hysteresis width of window
comparator (OI)
b070
Operation level at O
disconnection
Operation level at OI
b071
disconnection
b075
Ambient temperature setting
b078
Watt-hour clearance
Watt-hour display gain
b079
b082
Start frequency
Carrier frequency
b083
b084
Initialization mode (parameters
or trip history)
" b " F u n c t i o n
D e s c r i p t i o n
Four option codes:
00Disable
01Decelerates to a stop
02Decelerates to a stop with DC
bus voltage controlled
03Decelerates to a stop with DC
bus voltage controlled, then
restart
Setting of DC bus voltage to start
controlled decel. operation. Range is
0.0 to 1000.0
Setting the OV-LAD stop level of
controlled decel. operation. Range is
0.0 to 1000.0
Range is 0.01 to 3600.0
Setting of initial freq. drop.
Range is 0.0 to 10.0 Hz
Set range, 0.to100. {lower limit:
b061 + b062 x 2} (%)
Set range, 0.to100. {upper limit:
b060 - b062 x 2} (%) (Max of 0% )
Set range, 0.to10. {upper limit:
(b060 - b061) / 2} (%) (Max of 10%)
Set range, 0.to100. {lower limit:
b064 + b065 x 2} (%) (Min of 0%)
Set range, 0.to100. {upper limit:
b063 - b065 x 2} (%) (Max of 0%)
Set range, 0.to10. {upper limit:
(b063 - b064) / 2} (%) (Max of 10%)
Set range, 0 to 100%, or "no"
(ignore)
Set range, 0 to 100%, or "no"
(ignore)
Set range is,
-10~50 C
Two option codes:
00OFF
01ON (press STR then clear)
Set range is,
1.~1000.
Sets the starting frequency for the
inverter output, range is 0.01 to 9.99
Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0 to
15.0 kHz (derating required
depending on the model)
Select initialized data, five option
codes:
00Initialization disabled
01Clears Trip history
02Initializes all Parameters
03Clears Trip history and
initializes all parameters
04Clears Trip history and
initializes all parameters and
EzSQ program
63
Run
D e f a u l ts
Mode
I n i t i a l
U n i ts
Edit
d a ta
00
220.0/
V
440.0
360.0/
V
720.0
1.0
s
0.0
Hz
100.
%
0.
%
0.
%
100.
%
0.
%
0.
%
*
no
1
*
1
no
C
40
00
1.
*
1
0.50
Hz
*
2.0
kHz
1
00