F u n c .
N a m e
C o d e
b050
Controlled deceleration on
power loss
DC bus voltage trigger level of
b051
ctrl. decel.
Over-voltage threshold of ctrl.
b052
decel.
b053
Deceleration time of ctrl. decel.
b054
Initial freq. drop of ctrl. decel.
Maximum-limit level of window
b060
comparator (O)
b061
Minimum-limit level of window
comparator (O)
Hysteresis width of window
b062
comparator (O)
b063
Maximum-limit level of window
comparator (OI)
Minimum-limit level of window
b064
comparator (OI)
b065
Hysteresis width of window
comparator (OI)
b070
Operation level at O
disconnection
Operation level at OI
b071
disconnection
b075
Ambient temperature setting
b078
Watt-hour clearance
Watt-hour display gain
b079
b082
Start frequency
Carrier frequency
b083
b084
Initialization mode (parameters
or trip history)
" b " F u n c t i o n
D e s c r i p t i o n
Four option codes:
00Disable
01Decelerates to a stop
02Decelerates to a stop with DC
bus voltage controlled
03Decelerates to a stop with DC
bus voltage controlled, then
restart
Setting of DC bus voltage to start
controlled decel. operation. Range is
0.0 to 1000.0
Setting the OV-LAD stop level of
controlled decel. operation. Range is
0.0 to 1000.0
Range is 0.01 to 3600.0
Setting of initial freq. drop.
Range is 0.0 to 10.0 Hz
Set range, 0.to100. {lower limit:
b061 + b062 x 2} (%)
Set range, 0.to100. {upper limit:
b060 - b062 x 2} (%) (Max of 0% )
Set range, 0.to10. {upper limit:
(b060 - b061) / 2} (%) (Max of 10%)
Set range, 0.to100. {lower limit:
b064 + b065 x 2} (%) (Min of 0%)
Set range, 0.to100. {upper limit:
b063 - b065 x 2} (%) (Max of 0%)
Set range, 0.to10. {upper limit:
(b063 - b064) / 2} (%) (Max of 10%)
Set range, 0 to 100%, or "no"
(ignore)
Set range, 0 to 100%, or "no"
(ignore)
Set range is,
-10~50 C
Two option codes:
00OFF
01ON (press STR then clear)
Set range is,
1.~1000.
Sets the starting frequency for the
inverter output, range is 0.01 to 9.99
Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0 to
15.0 kHz (derating required
depending on the model)
Select initialized data, five option
codes:
00Initialization disabled
01Clears Trip history
02Initializes all Parameters
03Clears Trip history and
initializes all parameters
04Clears Trip history and
initializes all parameters and
EzSQ program
63
Run
D e f a u l ts
Mode
I n i t i a l
U n i ts
Edit
d a ta
00
220.0/
V
440.0
360.0/
V
720.0
1.0
s
0.0
Hz
100.
%
0.
%
0.
%
100.
%
0.
%
0.
%
*
no
1
*
1
no
C
40
00
1.
*
1
0.50
Hz
*
2.0
kHz
1
00