Hitachi WJ200 Series Quick Reference Manual page 63

Hide thumbs Also See for WJ200 Series:

Advertisement

F u n c .
N a m e
C o d e
A104
[OI] input active range end
current
A105
[OI] input start frequency
select
A131
Acceleration curve constant
Deceleration curve constant
A132
A141
A input select for calculate
function
B input select for calculate
A142
function
Calculation symbol
A143
ADD frequency
A145
ADD direction select
A146
Curvature of EL-S-curve at the
A150
start of acceleration
A151
Curvature of EL-S-curve at the
end of acceleration
A152
Curvature of EL-S-curve at the
start of deceleration
" A" F u n c t i o n
D e s c r i p t i o n
The ending point (offset) for the
current input range,
range is A103 value to 100.(%)
Two options; select codes:
00Use offset (A101 value)
01Use 0Hz
Range is 01(smallest swelling) to
10(largest swelling).
Range is 01 to 10.
Seven options:
00Operator
01VR
02Terminal [O] input
03Terminal [OI] input
04RS485
05Option
07Pulse train input
Seven options:
00Operator
01VR
02Terminal [O] input
03Terminal [OI] input
04RS485
05Option
07Pulse train input
Calculates a value based on the
A input source (A141 selects)
and B input source (A142
selects).
Three options:
00ADD (A input + B input)
01SUB (A input - B input)
02MUL (A input * B input)
An offset value that is applied to
the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.0 Hz
Two options:
00Plus (adds A145 value to
the output frequency setting)
01Minus (subtracts A145 value
from the output frequency
setting)
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
57
D e f a u l ts
Run
Mode
I n i t i a l
U n i ts
Edit
d a ta
*
100.
1
*
1
00
*
1
02
*
02
1
*
1
02
*
1
03
*
00
1
*
0.00
1
*
1
00
10.
10.
10.
%
Hz
%
%
%