Hitachi WJ200 Series Quick Reference Manual page 85

Hide thumbs Also See for WJ200 Series:

Advertisement

Option
Terminal
Code
Symbol
21
ZS
Zero Hz Speed
Detection Signal
22
DSE
Speed Deviation
Excessive
23
POK
Positioning Completion
24
FA4
Frequency Arrival Type
4–Over frequency
25
FA5
Frequency Arrival Type
5–Set frequency
OL2
Overload Advance
26
Notice Signal 2
ODc
Analog Voltage Input
27
Disconnect Detection
OIDc
Analog Current input
28
Disconnect Detection
31
FBV
PID Second Stage
Output
NDc
Network Disconnect
32
Detection
LOG1
Logic Output Function 1
33
LOG2
Logic Output Function 2
34
35
LOG3
Logic Output Function 3
39
WAC
Capacitor Life Warning
Signal
WAF
Cooling Fan Warning
40
Signal
Output Function Summary Table
Function Name
ON
Output frequency falls below the threshold
specified in C063.
OFF
Output frequency is higher than the threshold
specified in C063.
ON
Deviation of speed command and actual speed
exceeds the specified value P027.
OFF
Deviation of speed command and actual speed
does not exceed the specified value P027.
ON
Positioning is completed.
OFF
Positioning is not completed.
ON
When output to motor is at or above the set freq.,
even if in accel (C045) or decel (C046) ramps.
OFF
When output to motor is OFF, or at a level below
the set frequency.
ON
When output to motor is at the set frequency,
during accel (C045) and decel (C046).
OFF
When output to motor is OFF, or is not at a level of
the set frequency.
ON
When output current is more than the set
threshold (C111) for the overload signal.
OFF
When output current is less than the set threshold
for the overload signal.
ON
When the [O] input value < b070 setting (signal
loss detected).
OFF
When no signal loss is detected.
ON
When the [OI] input value < b071 setting (signal
loss detected).
OFF
When no signal loss is detected.
ON
Transitions to ON when the inverter is in RUN
Mode and the PID Process Variable (PV) is less
than the Feedback Low Limit (C053).
OFF
Transitions to OFF when the PID Process Variable
(PV) exceeds the PID High Limit (C052), and
transitions to OFF when the inverter goes from
Run Mode to Stop Mode.
ON
When the communications watchdog timer (period
specified by C077) has time out.
OFF
When the communications watchdog timer is
satisfied by regular communications activity.
ON
When the Boolean operation specified by C143
has a logical "1" result.
When the Boolean operation specified by C143
OFF
has a logical "0" result.
ON
When the Boolean operation specified by C146
has a logical "1" result.
OFF
When the Boolean operation specified by C146
has a logical "0" result.
When the Boolean operation specified by C149
ON
has a logical "1" result.
OFF
When the Boolean operation specified by C149
has a logical "0" result.
ON
Lifetime of internal capacitor has expired.
OFF
Lifetime of internal capacitor has not expired.
ON
Lifetime of cooling fan has expired.
OFF
Lifetime of cooling fan has not expired.
79
Description