Pioneer QUANTUM INVERTER Series Service & Troubleshooting Manual page 114

Hide thumbs Also See for QUANTUM INVERTER Series:
Table of Contents

Advertisement

LED Flash Frequency:
2.2
Error Display (For Some Outdoor Units)
There are 2 LED lights (RED color and GREEN color) welded in outdoor main board. After power on, LED show
different actions when encounter different problems.
No.
Problem
1
Standby normally
2
Operate normally
3
Compressor driven chip EEPROM parameter error
4
IPM malfunction or IGBT over-current protection
5
Over voltage or too low voltage protection
6
Inverter compressor drive error
7
Inverter compressor drive error
Communication error between outdoor main chip and
8
compressor driven chip
... ...
Troubleshooting
LED(GREEN)
LED(RED)
ON
OFF
OFF
ON
ON
FLASH
FLASH
OFF
ON
ON
OFF
FLASH
FLASH
LIGHT
FLASH
FLASH
6
Solution
-
-
TS19
TS30
TS31
TS34
TS34
TS19