Pioneer QUANTUM INVERTER Series Service & Troubleshooting Manual page 30

Hide thumbs Also See for QUANTUM INVERTER Series:
Table of Contents

Advertisement

No.
Name
1
Power Supply
2
S
3
4-WAY
4
AC-FAN
5
HEAT2
6
TP T4 T3
7
PMV
8
HEAT1
9
DC-FAN
10
TESTPORT
11
FAN_IPM
12
COMP_IPM
U
13
V
W
14
EE_PORT
Note: This section is for reference only. Please take practicality as standard.
CN#
CN6
Earth: connect to Ground
CN7
N_in: connect to N-line (208-230V AC input)
CN8
L_in: connect to L-line (208-230V AC input)
CN2
S: connect to indoor unit communication
CN60
connect to 4 way valve, 208-230V AC when is ON.
CN5
connect to AC fan
CN19
connect to chassis heater, 208-230V AC when is ON
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
CN17
temp. sensor TP
CN18
connect to Electric Expansion Valve
CN16
connect to compressor heater, 208-230V AC when is ON
CN414
connect to DC fan
CN23
used for testing
IPM501
IPM for DC fan
IPM1
IPM for compressor
CN27
connect to compressor
CN28
0V AC (standby)
CN29
200-300V AC (running)
CN505
EEPROM programer port