Pioneer QUANTUM INVERTER Series Service & Troubleshooting Manual page 28

Hide thumbs Also See for QUANTUM INVERTER Series:
Table of Contents

Advertisement

No.
Name
1
CN1A
2
HEAT1
3
4-WAY
4
HEAT2
5
AC-FAN
6
PMV
7
TESTPORT
8
TP T4 T3
9
DC-FAN
10
FAN_IPM
W
11
V
U
12
COMP_IPM
Note: This section is for reference only. Please take practicality as standard.
CN#
CN3
Earth: connect to Ground
CN1
N_in: connect to N-line (208-230V AC input)
CN2
L_in: connect to L-line (208-230V AC input)
CN16
S: connect to indoor unit communication
CN17
connect to compressor heater, 208-230V AC when is ON
CN60
connect to 4 way valve, 208-230V AC when is ON.
CN15
connect to chassis heater, 208-230V AC when is ON
CN25
connect to AC fan
CN31
connect to Electric Expansion Valve
CN6
used for testing
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
CN21/CN22
temp. sensor TP
CN7
connect to DC fan
IPM 501
IPM for DC fan
CN28
connect to compressor
CN29
0V AC (standby)
CN30
10-200V AC (running)
IPM 301
IPM for compressor
Specifications
Meaning
19