Komatsu ecot3 Operation And Maintenance Manual page 192

Hide thumbs Also See for ecot3:
Table of Contents

Advertisement

OPERATION
OPERATION
REMARK
Regardless of the ambient temperature, it is possible to start the
engine preheating manually.
1. Turn the key in starting switch (3) to the left from OFF position
(A). The preheating monitor lights up and engine preheating
starts.
(Preheating continues while the key in starting switch (3) is held
at the left position.)
2. The preheating monitor starts lighting approximately 30
seconds after preheating starts and then goes off in
approximately 10 seconds.
3. After the preheating monitor goes off, turn the key in starting
switch (3) to START position (C). The engine will start.
If the engine cannot be started with the above procedure, wait for
at least 2 minutes, then start again from Step 1.
Turbo protect function
The turbo protect function is a function to protect the turbocharger by keeping the engine speed at less than 1000
rpm immediately after the engine is started.
When the turbo protect function is actuated, the engine speed is held at less than 1000 rpm, regardless of the
position of the fuel control dial.
When the turbo protect function is actuated, the engine speed is held at less than 1000 rpm, even if the fuel control
dial is operated.
When the turbo protect function is canceled, the engine speed is set to the speed for the position of the fuel control
dial.
The relationship between the length of time of actuating the
turbo protect function and the temperature of the engine coolant
is as shown in the table.
MACHINE OPERATIONS AND CONTROLS
MACHINE OPERATIONS AND CONTROLS
Coolant
temperature
Above 10 ° C (50 ° F)
10 to -10 ° C
Change 0 to 20
(50 to 14 ° F)
below -10 ° C (14 ° F)
Turbo protect
time (sec.)
0
20
3 - 135