Event Notification Response

When you choose Event Notification, ASUS Storage Management sends popup
and/or email messages regarding its status. The messages you see depend on
your notification selection and what is currently happening in the ASUS Storage.
See ―Setting-up User Event Subscriptions‖ on page 77.
The table below cites:
Reported Events – Events that require you to take action
Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
Battery (page 370)
Blowers (page 371)
Cache (page 372)
Controller (page 372)
Disk Array (page 372)
Drive Interface Controller
(page 373)
Enclosure (page 373)
Event Log (page 373)
Host Interface Controller
(page 374)
Logical Drive (page 374)
Media Patrol (page 375)
Online Capacity Expansion
(page 376)
Reported Event
Battery
Battery temperature is
above the threshold
Battery temperature is
normal
Battery capacity is below
the threshold
PDM (page 376)
Physical Disk (page 377)
PSU (Power Supply Units)
(page 378)
RAID Level Migration (page 379)
Rebuild (page 380)
Redundancy Check (page 380)
Resource (page 381)
Spare Check (page 381)
Spare Drives (page 381)
SMART (page 382)
Synchronization (page 382)
System (ASUS Storage) (page 382)
Transition (page 382)
Watermark (page 383)
The battery is too hot. Verify proper airflow around
the through the ASUS Storage. If airflow is OK,
replace the battery. See page 314.
Normal.
Battery is drained. Run battery reconditioning. See
page 139 (ASUS Storage Management) or page 220
(CLU).