Figure 007-29 Outline Of The Paging Equipment Connection - NEC NEAX 2000 IVS Installation Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

NAP 200-007
Sheet 36/56
Termination of Cables on the MDF
(10) Paging Equipment
The cross connection for a customer owned paging equipment is shown in
007-31, as an example.
Requirement for the Paging Equipment
Input Impedance
Control Method
Note:
The current capacity of the relay driver (PN-DK00 card) is 0.125 A.
(a) Outline of the Connection
: 600 ohm
: Start - Ground Start Note
: Stop - Ground Off (Open)
PBX
PN-4COT Card
PN-DK00 Card
PZ-PW86 Card
G

Figure 007-29 Outline of the Paging Equipment Connection

For Amplifier Input
MDF
G
ND-45492 (E)
Figure 007-29
Paging Equipment
G
For Control
through
Figure
CHAPTER 3
Page 121
Revision 2.0