NAP 200-010
Sheet 1/3
System Initialization and System Data
Entry
1. System Initialization
There are two methods for System Initialization. The first method is to Clear All Data, except LEN0000 as
a CAT terminal, and then program the System Data. The second method is to use the Resident System Pro-
gram, which causes the system to configure itself automatically to the default settings, wherever the line/
trunk cards are installed. Refer to the System Data Sheet, for the default settings.
Turn on the "SW1" switch on all the PZ-PW86 units.
The "ON" lamp must be lit on all the PZ-PW86 units.
1.1. All Clear, Except LEN0000 CAT
STEP 1:
On the MP Card, set SW3 to "B" and press SW1.
STEP 2:
When the "MN" lamp on the system is lit, set SW3 to the "0" position and press SW1.
The operating mode has been changed to the ON LINE mode.
Refer to the Circuit Card Manual for information on switch settings.
Note:
1.2. Resident System Program
STEP 1:
Mount the Line/Trunk cards into PIM.
STEP 2:
On the MP Card, set SW3 to "C" and press SW1.
After 30 to 40 seconds, the "MN" lamp turns on.
The system has loaded the Resident System Program.
Note:
If the "MJ" lamp is lit, repeat Step 2.
STEP 1:
Set SW3 to the "0" position and press SW1.
The operating mode has been changed to the ON LINE mode.
Note:
Refer to the System Data Sheet for additional information on the Resident System Program and the initial-
ization of the system without a MAT (enabling CAT mode).
ND-45492 (E)
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
CHAPTER 3
Page 151
Revision 2.0