Fujitsu PRIMERGY RX200 S2 User Manual page 52

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

5
Confirm that the following log is displayed in Log Information
Viewer of GAM.
Event ID
Description
6
Pull out the plastic lever 90 degrees towards you, and also pull out
the likely-to-fail hard disk unit 1 to 3cm to disconnect it from the
SCSI bus.
7
Wait 1 minute or more.
8
Pull out the likely-to-fail hard disk from the hard disk bay.
9
Install a new hard disk in the hard disk bay where the likely-to-fail
hard disk was previously installed.
10
Double-click the Critical logical drive (marked with ! in yellow) in
the [Controller View] window of GAM.
The [Logical Drive Information] window appears.
11
Click [Rebuild].
Rebuild starts.
When rebuilding is started, the Fault LED of the replaced hard disk that was lit starts to blink,
and turns off after rebuilding is completed.
After its completion, make sure that the status of the logical drive has changed from
"Critical" to "OnLine" using [Logical Drive Information] of GAM.
52
: S-12
: A physical disk has failed.
Do not pull out the hard disk unit completely from the server at this point.
If the rebuild does not start, scan the device.