Fujitsu PRIMERGY RX200 S2 User Manual page 66

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
notatio
n
134
(0x86)
135
(0x87)
136
(0x88)
137
(0x89)
138
(0x8a)
139
(0x8b)
140
(0x8c)
141
(0x8d)
142
(0x8e)
143
(0x8f)
66
Type
Log item
Error
Logical drive has
been made offline.
Error
Logical drive is
critical.
Infor
Logical drive has
mati
been placed online.
on
Infor
An automatic
mati
rebuild has started
on
on logical drive.
Infor
A manual rebuild
mati
has started on
on
logical drive.
Infor
Rebuild on logical
mati
drive is over.
on
Warn
Rebuild on logical
ing
drive is cancelled.
Error
Rebuild stopped
with error.
Error
Rebuild stopped
with error. New
device failed.
Error
Rebuild stopped
because logical
drive failed.
Description
Due to multiple hard
disk failures, the logical
drive is now in Offline
state.
Due to one of the hard
disks failing, the logical
drive is now in Critical
state.
The logical drive is
now in Online state.
The following are
possible causes:
• Rebuilding com-
pleted.
Rebuild started.
Rebuild started.
Rebuild completed.
Rebuild was canceled.
Rebuild terminated
abnormally.
Rebuild terminated
abnormally due to a
bad hard disk for the
rebuild.
• The source disk of
the rebuild failed.
• Due to many bad
blocks in the source
disk of the rebuild,
the rebuild termi-
nated abnormally.
Action
Take corrective action
using the Multi Dead
function.
Replace the Dead hard
disk and rebuild.
Not required.
Not required.
Not required.
Not required.
Re-execute the rebuild.
Check the logs
surrounding the process
and perform necessary
actions.
Replace the hard disk and
perform the rebuild
process again.
Take corrective action
using the Multi Dead
function.