Fujitsu PRIMERGY RX200 S2 User Manual page 67

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
Type
notatio
n
148
(0x94)
Infor
mati
on
149
(0x95)
Infor
mati
on
153
(0x99)
Error
156
(0x9c)
Error
157
(0x9d)
Warn
ing
158
(0x9e)
Error
159
(0x9f)
Error
384
(0x180)
Infor
mati
on
386
(0x182)
Warn
ing
Log item
A logical drive has
A new logical drive
been found.
was detected. The
following are possible
causes:
• The system was
A logical drive has
A logical drive was
been deleted.
deleted.
Bad Blocks found.
A bad block was
detected during a
rebuild.
Bad data blocks
Bad blocks were found
found. Possible data
in multiple hard disks
loss.
in the same location.
Logical drive LUN
LUN mapping of the
mapping has been
system drive was
written to config.
written to the
configuration.
Attempt to read data
Attempted to read data
from block that is
logged in the BDT
marked in Bad Data
table.
Table.
Data for Disk Block
Due to a problem with
has been lost due to
the logical drive, cache
Logical Drive
data could not be
problem.
written to the hard disk.
Array management
GAM Server started
server software
successfully.
started successfully.
Internal log
Due to many
structures getting
configuration changes,
full, PLEASE
the configuration
SHUTDOWN AND
change table is full.
RESET THE
SYSTEM IN THE
NEAR FUTURE.
Description
Not required.
restarted.
Not required.
If a corrupted file is found,
restore it from the backup.
If a corrupted file is found,
restore it from the backup.
Not required.
If a corrupted file is found,
restore it from the backup.
Check the logs
surrounding the process
and perform necessary
actions.
Not required.
After successfully
shutting down, turn off
and then turn on the
server.
If the same log is not
deleted, replace the SCSI
array controller.
Action
B List of GAM Error Codes
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents