Fujitsu PRIMERGY RX200 S2 User Manual page 70

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
notatio
n
428
(0x1ac)
512
(0x200)
514
(0x202)
515
(0x203)
516
(0x204)
517
(0x205)
518
(0x206)
640
(0x280)
641
(0x281)
700
(0x2bc)
701
(0x2bd)
800
(0x320)
801
(0x321)
70
Type
Log item
Error
Mirror Race on
critical drive.
Infor
System started.-
mati
on
Infor
User logged in.-
mati
on
Infor
User logged out.-
mati
on
Infor
Server alive.
mati
on
Error
Lost connection to
server, or server is
down.
Infor
Automatic reboot
mati
count has changed.
on
Warn
Channel Failed.
ing
Warn
Channel Online.
ing
Warn
Event Log Empty.
ing
Warn
Event Log Entries
ing
Lost.
Warn
New Configuration
ing
Received.
Warn
Configuration
ing
Cleared.
Description
The logical drive went
critical.
The server or GAM
Server started.
The user logged in to
the server.
The user logged out of
the server.
• Reconnected to the
server.
• The server restarted.
• The network connec-
tion to the server was
lost.
• The server shut
down.
The automatic reboot
count changed.
The channel failed.
The channel was
restored.
The event log is now
empty.
The event log entry was
lost.
A new configuration
was set.
The array configuration
was cleared.
Action
Replace the hard disk and
perform the rebuild
process.
Not required.
Not required.
Not required.
Not required.
Check the network.
Check that the server is
running.
Not required.
Replace the SCSI BP or
SCSI cable.
If the issue is not resolved,
replace the SCSI array
controller.
Not required.
Not required.
Not required.
Not required.
Not required.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents