Type
Log item
Error
A physical disk
failed because write
operation of the
'Configuration On
Disk' failed.
Error
A physical disk
failed because write
operation of 'Bad
Data Table' failed.
Error
Physical device
status changed to
offline.
Error
Physical device
status changed to
rebuild.
Error
Physical device ID
did not match.
Error
Physical device
failed to start.
Error
Physical drive
missing on startup.
Warn
Rebuild startup
ing
failed due to lower
disk capacity.
Infor
Physical disk type is
mati
not approved by
on
vendor.
Description
A hard disk failed.
A hard disk is now in
offline state.
A hard disk is now in
rebuild state.
A hard disk ID
mismatch was detected.
Failed to start a hard
disk.
No hard disk was
detected during startup.
Insufficient hard disk
space to perform the
rebuild.
An unsupported hard
disk is installed.
Action
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function.
If the hard disk failed,
replace it and perform the
rebuild process.
Not required.
Not required.
If the hard disk failed,
replace it and perform the
rebuild process.
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function.
Replace the hard disk with
a disk of the same model
(with the same capacity
and speed) as the other
disks, and then perform
the rebuild process.
Check to see whether the
appropriate hard disks are
installed. If the issue is not
resolved, replace the
baseboard.