41
(0x29)
Error
42
(0x2a)
Error
43
(0x2b)
Error
44
(0x2c)
Error
45
(0x2d)
Error
46
(0x2e)
Error
47
(0x2f)
Error
Log item
A physical disk
A hard disk failed.
failed because of
busy status or parity
error.
A physical disk set
Make Offline was
to failed state by
executed.
host.
A physical disk
failed because
access to the device
met with a selection
time out.
A physical disk
failed because of a
sequence error in the
SCSI bus phase
handling.
A physical disk
A hard disk failed.
failed because
device returned an
unknown status.
A physical disk
failed because
device is not ready.
A physical disk
failed because
device was not
found on start up.
Description
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function.
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function. Do not use Make
Offline unless directed to
do so.
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function.