Fujitsu PRIMERGY RX200 S2 User Manual page 68

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
notatio
n
388
(0x184)
389
(0x185)
390
(0x186)
391
(0x187)
395
(0x18b)
396
(0x18c)
397
(0x18d)
398
(0x18e)
68
Type
Log item
Error
Controller is dead.
System is
disconnecting from
this controller.
Warn
Controller has been
ing
reset.
Infor
Controller is found.
mati
on
Error
Controller is gone.
System is
disconnecting from
this controller.
Error
Controller is gone.
System is
disconnecting from
this controller.
Infor
Controller powered
mati
on.
on
Infor
Controller is online.
mati
on
Error
Controller is gone.
System is
disconnecting from
this controller.
Description
The SCSI array
controller failed.
The SCSI array
controller received a
reset command.
• A new SCSI array
controller was
detected.
• GAM Server
restarted.
• The system was
restarted.
• Power supplied to
the SCSI array con-
troller was cut off.
• The SCSI array con-
troller was removed
from the system.
A new SCSI array
controller was installed.
A SCSI array controller
came online.
• Power supplied to
the SCSI array con-
troller was cut off.
• The SCSI array con-
troller was removed
from the system.
Action
Replace the baseboard.
Because the firmware is
implementing a recovery,
there is no problem as
long as there are no Dead
hard disks.
Not required.
Replace the baseboard.
Not required.
Not required.
Replace the baseboard.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents