Detection Zone Additions; Warning Zone; Contour Measurement - Siemens SIMATIC FS600 Instruction Manual

Table of Contents

Advertisement

14.3

Detection Zone Additions

Addition with deactivated
dust suppression
Addition for activated dust
suppression
Addition if retro-reflectors or very
shiny surfaces such as certain
metals or ceramics are present
in the scanning plane
Table 14.3-1:
14.4

Warning zone

Detection range
Reflectance factor
Object size
Response time
Number of warning zones
Output
Table 14.4-1:
14.5

Contour Measurement

Measurement range
Reflectance factor
Output
Radial resolution
Lateral resolution
Table 14.5-1:
100
Detection Zone Additions
Technical data – warning zone
Technical data – contour measurement
83 mm
83 mm (for a detection zone size < 3.5 m)
100 mm (for a detection zone size ≥ 3.5 m)
0 mm (more than 1.2 m behind the detection zone
line)
110 mm (in the detection zone or up to 1.2 m
behind detection zone line)
0 -15 m
min. 20 %
150 x 150 mm
Double evaluation: 80 ms (corresponds to 2
scans), up to 16 scans can be selected (640 ms)
4/8 (selectable via switch inputs)
PNP transistor output, max. 100 mA
0 - 50 m
min. 20 %
Serial interface RS 232 (10 m),
RS 422 (50 m)
5 mm
0.36°