Status displays on the SIMATIC
FS600 Laser Scanner
1a
1b
1a= Sensor function
1b= Errors on the zone pair control inputs,
Light flashing at 2 Hz
2a= Warning field is occupied
2b= Optical window is dirty,
Light flashing at 2 Hz
2c = ConfigPlug configuration see Chapter 10.5 not
compatible, Light flashing at 4 Hz
3 = OSSDs are turned off
4 = OSSDs are turned on
5a= Restart inhibit locked,
Continuous light
5b= Optical window is dirty,
Light flashing at 2 Hz
5c = Fault, light flashing at 4 Hz
16
Protective caps
2a
2b
2c
Assignment of
interface X1
FP 4
FP 3
FP 2
Alarm 1
FP 1
UB
Restart
GND
LEDs
Assignment of interface
X2 as RS232 port
Reserved
TxD
RxD
Reserved
GND/shield
5a
5b
5c
Assignment of interface
X2 as RS422 port
Tx +
Tx -
Rx -
Rx +
GND/shield
8
Alarm 2
15
7
Reserved
14
6
Reserved
13
5
OSSD2
12
4
OSSD1
11
3
Reserved
10
2
Reserved
9
1
1
RS232 detection
6
2
Reserved
7
3
Reserved
8
4
Reserved
9
5
1
RS422 detection
6
2
Reserved
7
3
Reserved
8
4
Reserved
9
5
Connection
Pin 5 to Pin 6