Maintenance And Testing; Test Before First Startup By Person Qualified And Authorized To Perform The Task; Extended Shutdown Of The Simatic Fs600 Laser Scanner - Siemens SIMATIC FS600 Instruction Manual

Table of Contents

Advertisement

11

Maintenance and Testing

When placing the system in service for the first time, when it has been out of service for
some time, after conversions and repair work, make certain the scanner and any other
safety parts are checked specifically for the application and operation by the responsible
trained specialist. This must be done taking into consideration applicable local
requirements, especially for guidelines on machines and using work material and work
safety guidelines. If the correct functionality is not clearly confirmed or if safety-related
parameters have been changed, turn the machine or vehicle off immediately. Stopgap
measures are not permitted.
Please comply with the safety notes in Chapter 3!
11.1
Test before First Startup by Person Qualified and Authorized to Perform
the Task
Check in accordance with the guidelines cited above, using the checklists provided
below if necessary to verify that the protective equipment has been properly
attached is connected to the control system electrically and that its effect works in
all operating modes of the machine or vehicle.
The result of the test must be documented, along with the scanner setting, in an
understandable form. Printouts of scanner parameters and all defined detection
zone contours must be included with the materials. Keep these
where they are inaccessible for unauthorized personnel.
During initial startup, you should anticipate unexpected behavior in the
machine or vehicle. Because of this, people must be kept out of the danger area.
Operating personnel must be instructed by trained specialists before starting work.
Instruction is part of the area of responsibility of the machine operator.
Ensure that a daily test is performed. Please take note in this regard of the "Daily
Test with the Test Piece Performed by Responsible Operating Personnel".
11.2

Extended Shutdown of the SIMATIC FS600 Laser Scanner

If a system is taken out of operation and the SIMATIC FS600 Laser Scanner is placed
in storage for later use with other machines/vehicles, the factory settings should be
restored. Please see the chapter entitled "Setting Detault Values in the Scanner" in the
SIMATIC FS600 Parameterization Software LS4soft operating instructions.
83

Advertisement

Table of Contents
loading