11.4.1

Checklist for Daily Test of Stationary Applications by Responsible Operating

Personnel

1) Are there any problems in the external state of the protective
equipment, the cable, cable connections and any command
devices or any command devices?
2) Are the fastening screws in the mounting system firmly
connected?
3) Are the fastening screws in the SIMATIC FS600 Laser Scanner
firmly connected?
4) Are both protective caps (X1 and X2) screwed on and are the
firmly in place?
5) Do the safety equipment and command devices show any safety-
relevant changes or gaps in safety (e.g. changes in access
possibilities or changes in the surrounding area)?
6) If the protective function of the SIMATIC FS600 Laser Scanner is
present for all required monitoring cases (e.g. testing the switch-
off function with a test piece along the detection zone contour, the
LED3 for SIMATIC FS600 Laser Scanner must light up with each
attempt and the movement that poses a danger must be stopped
immediately. Possibility of danger to the person running the test
must be excluded)?
7) Is the startup test/restart interlock (if there is one) working?
8) Does the base marking match the detection zone contour?
9) Do the necessary detection zones match the configuration
protocol?
10) If correct functionality is not certain or id the SIMATIC FS600
Laser Scanner LED 5 is flashing, take the machine out of
operation immediately. Are any doubts resolved?
If the answer to any of the questions above is No, have the machine checked by a
trained specialist.