<WSW29>
Selector No.
1
Compression threshold level for
voice signals inputted via the
I
telephone line in the built-in TAD
3
operation (Not used.)
4
Compression threshold level for
voice signals inputted via the
I
handset in the built-in TAD
6
operation (Not used.)
Impedance switching control in
7
pulse dialing
Prompt beep when the memory
8
area for the activity report
becomes full
Note:
• Selectors 7 and 8 are applicable only to the European versions.
• Selector 8: Prompt beep for activity report
This selector determines whether or not to beep if the memory area for the activity report
becomes full, for prompting you to print out the report. (Printing it out will clear the memory
area.)
Function
No. 1 2 3
No. 4 5 6
App. 1-36
Setting and Specifications
0 0 0: -47.0 dBm
(A)
0 0 1: -48.5 dBm
(B)
0 1 0: -50.0 dBm
(C)
0 1 1: -51.5 dBm
(D)
1 0 0: -53.0 dBm
(E)
1 0 1: -54.5 dBm
(F)
1 1 0: -56.0 dBm
(G)
1 1 1: OFF
(H)
0 0 0: -44.0 dBm
(A)
0 0 1: -45.5 dBm
(B)
0 1 0: -47.0 dBm
(C)
0 1 1: -48.5 dBm
(D)
1 0 0: -50.0 dBm
(E)
1 0 1: -51.5 dBm
(F)
1 1 0: -53.0 dBm
(G)
1 1 1: OFF
(H)
0: OFF
1: ON
0: No
1: Yes
Confidential