Brother DCP-8085DN Service Manual page 491

Laser fax/mfc
Hide thumbs Also See for DCP-8085DN:
Table of Contents

Advertisement

<WSW50>
Selector No.
Percentage voltage for
interpreting the external
1
telephone as being hooked up
(based on the network's
2
standard voltage)
(Not used.)
DC mask curve table to be
applied when the line is
3
connected
(Not used.)
AC impedance to be applied
4
when the line is connected
(Not used.)
Current control to be applied
5
immediately after connection of
the line
6
(Not used.)
AC voltage threshold for
7
detection of ring
8
(Not used.)
Function
No. 1 2
0: Apply the initial value specified by local
1: Apply table DC5 prepared specially
0: 600Ω termination
1: ZR termination
No. 5 6
No. 7 8
App. 1-57
Setting and Specifications
0 0: 50 %
0 1: 80 %
1 0: 30 %
1 1: No detection
regulations
0 0: Standard
0 1: Increase start-up current for
termination
1 0: Fine current control for
termination
1 1: Not used. (equal to "0, 0")
0 0: 19 V
0 1: 11 V
1 0: 25 V
1 1: 31 V
Confidential

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc-8480dnMfc-8880dnMfc-8890dwDcp-8080dn

Table of Contents