Error Codes; Error Indication - Brother DCP-8085DN Service Manual

Laser fax/mfc
Hide thumbs Also See for DCP-8085DN:
Table of Contents

Advertisement

3. ERROR CODES

This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the
LCD, which in turn helps the end user to quickly find out the problem.
3.1

Error Indication

Error
codes
Replacement time of the drum
1E
unit
Two or more optional trays are
1F
installed
Internal temperature sensor
24
failure
EEPROM of main PCB failure
35
HVPS PCB during standby
36
failure
Main PCB RAM failure
3B
EEPROM writing error
(Not applicable)
3C
EEPROM reading error
3D
(Not applicable)
EEPROM bus error
3E
(Not applicable)
No toner cartridge
44
Replacement time of the drum
50
unit
Replacement time of the paper
51
feed kit MP
Replacement time of the paper
52
feed kit T1
Replacement time of the paper
53
feed kit T2
Replacement time of the fuser
unit
54
Replacement time of the laser
55
unit
Back cover opened
56
Paper jam (Duplex tray)
57
Fuser unit failure
58
Refer
Problem
3-12
3-12
3-12
3-13
3-13
3-13
3-13
3-13
3-13
3-14
3-14
3-14
3-15
3-15
3-15
3-15
3-16
3-16
3-17
Error
to:
codes
Fuser unit failure (Detect fuser
59
failure at start-up)
Replace toner or Toner life end
63
Toner low
67
Temperature rise when heater is
68
off
Mis-connect center thermistor
69
connector
Fuser temperature does not
6A
detect 60°C within the specified
time (center thermistor)
Fuser temperature does not
detect 100°C within the
6B
specified time (center
thermistor)
Detect higher temperature error
6C
(center thermistor)
Detect lower temperature error
6D
(center thermistor)
Detect non temperature rising
6E
error (center thermistor)
Hardware detects extremely
6F
high temperature of the center
or side thermistors
Fuser motor error
70
Laser unit polygon mirror failure
71
Laser beam emission failure
72
Sensor of the inside
temperature for detection
75
detected higher than constant
temperature
Rapid temperature rising failure
76
(center thermistor)
Rapid temperature falling failure
78
(center thermistor)
No detection of main motor
7A
synchronous signal
Dirt on charged wire (detect
7D
discharge error)
3-9
Refer
Problem
3-17
3-17
3-17
3-18
3-18
3-19
3-19
3-19
3-19
3-19
3-19
3-20
3-20
3-20
3-20
3-21
3-21
3-21
3-21
Confidential
to:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc-8480dnMfc-8880dnMfc-8890dwDcp-8080dn

Table of Contents