NEC SigmaBlade N8406-040(F) User Manual page 126

8g fc switch
Table of Contents

Advertisement

IMPORTANT:
The ACT LED illuminates in umber temporarily while the 8G FC Switch is started.
If the ACT LED is in any status other than illuminating in green, an error occurs in the
8G FC Switch. If the error cannot be rejected in spite of required action, contact your
service representative.
Port status LED (located to the left of each port number)
LED status
OFF
Illuminating in green
Blinking in green
(irregular blinking)
Blinking in green
slowly
(1-sec interval)
Blinking in umber fast
(0.5-sec interval)
Illuminating in umber
Blinking in umber
slowly
(1-sec interval)
Blinking in umber fast
(0.5-sec interval)
Blinking in umber and
green alternately
IMPORTANT:
The Port status LED illuminates in umber temporarily while the 8G FC Switch is started.
If the error cannot be rejected in spite of required action, contact your service
representative.
Condition
No signals are sent to the SFP+
module, a proper cable is not
connected to the SFP+ module or
a fibre channel device is not
connected to the SFP+ module.
No traffics flow in the online status
(with a device onnected).
The port is in the online status and
traffics flow through the port.
Port is online and segmented,
indicating a loopback cable or
incompatible device.
The port is in the internal loop
status.
The port is receiving light or
signal, but is not online yet.
As a result of self-diagnosis, a
malfunction is found in the port
and the port is in the disable
status.
The Port is in the fault.
The port is in the bypass mode.
- 126 -
Required action
Check the SFP+ module, a proper
cable and fibre channel device
connectivity.
Check a fibre channel cable
connectivity and device
compatibility.
Use the "portEnable" command for
the port enabled.
If the status LEDs for all ports is
blinking umber slowly, use the
"switchEnable" command for the
switch enabled.
Check a fibre channel cable
connectivity and device
compatibility.
Check the connection of fibre
channel loop.

Advertisement