5. Troubleshooting

Read this section when any symptom of trouble occurs.
If the section explains the symptom, take an appropriate action as explained.
If the 8G FC Switch still fails to operate successfully after solving your problem, contact your service
representative.
8G FC Switch fails to start
Check the status of the 8G FC Switch according to "(1) ON/OFF conditions of LEDs" in Section 3
"Names and Features of Sections" described earlier in this guide.
If the slot containing the 8G FC Switch is suspected, check the following and take an appropriate
action.
Is the proper power supplied to the system?
→ Check if the Blade Enclosure (SIGMABLADE) is powered on according to the User's Guide of
the Blade Enclosure (SIGMABLADE).
Is the 8G FC Switch installed correctly?
→ Remove the 8G FC Switch once and reinstall it again. After the 8G FC Switch is removed,
wait for more than 30 seconds and then reinstall it.
Does the EM card work normally?
→ Check the Status LED on EM card or SIGMABLADE monitor. If the Status LED does not
illuminate in blue, refer to the User's Guide of the EM card and Blade Enclosure
(SIGMABLADE).
Does the Status LED on the 8G FC Switch blink in umber?
→ Refer to the User's Guide of Blade Enclosure (SIGMABLADE) for proper installation locations.
The CPU blade (containing mezzanine card) and the 8G FC Switch been installed in proper
position?
Does the Status LED on the 8G FC Switch illuminate in green?
→ Wait for three minites or longer for power-on the 8G FC Switch.