NEC 2400 Integration Manual page 119

Intuity integration with nec neax 2400 switch
Table of Contents

Advertisement

Table A-1. SID Error Codes and Descriptions
Code
Description
1
VM Comm Error
2
No Free VM_IN Packets
3
Excess Data -- VM_IN Pkts
5
Bad MWI Pkt
6
No Free Centrex Pkts
10
Excess Data - PBX_IN pkt
11
Kernel Error
12
No Free PBX_OUT Packets
13
Idle Task Not Enough Time
15
Bad PBX Pkts > 50%
16
Bad PBX Pkts > 5%
17
System Startup
19
System Powerdown
20
VM Comm Error > 5%
21
VM Comm Error > 50%
22
Boot Error: RTC
23
Boot Error: SCC
24
Boot Error: LED
25
Boot Error: Modem
26
Boot Error: DPRAM
27
Bad MWI Pkts > 50%
28
Bad MWI Pkts > 5%
29
PBX Comm Error > 5%
30
PBX Comm Error > 50%
31
Bad PBX Packet
32
Hardware Watchdog Reboot
33
Integration Stop
34
Integration Start
35
No Free PBX_IN Packets
36
Hardware Reset
37
VM Remote Reset
38
Software Reset
Type
Action
W
Check SMDI connection and parameters
W
Check SMDI connection and parameters
W
Check SMDI connection and parameters
W
Check SMDI connection and parameters
W
Check SMDI connection and parameters
W
Check MCI connection and parameters
E
W
Check MCI connection and parameters
W
I
Check MCI connection and parameters
I
Check MCI connection and parameters
I
No action required
I
No action required
E
Check SMDI connection and parameters
E
Check SMDI connection and parameters
E
Set time and date
E
E
E
E
I
Check SMDI connection and parameters
I
Check SMDI connection and parameters
E
Check MCI connection and parameters
E
Check MCI connection and parameters
W
Check MCI connection and parameters
E
I
No action required
I
No action required
W
Check MCI connection and parameters
I
No action required
I
No action required
I
No action required
Issue 2 December 1995
Error Logs
A-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 2400

Table of Contents