NEC 2400 Integration Manual page 26

Intuity integration with nec neax 2400 switch
Table of Contents

Advertisement

Introduction and Requirements for Integration
In addition to the hardware and software listed in Table 1-3, you must provide the
following administration on the NEAX 2400.
Program the PA-16LCQ analog ports to provide an adequate loop current
disconnect, or wink . The PA-16LCQ card provides a default value of
approximately 128ms wink. The wink can be increased to approximately
448ms with a firmware upgrade from NEC. Without the upgrade and the
increase, two items occur:
— Call holding times increase substantially because the default
— Call answer messages end with a reorder tone of approximately
Set the recall timer on the NEAX switch to an amount of time longer than
the ring-no-answer time. If you do not, calls blind transferred to
subscribers administered for forward on ring-no-answer recall back to the
INTUITY System channel.
Administer the INTUITY System to transfer calls to a station other than an
actual attendant console, for example a digital telephone capable of
displaying calling party information. The NEAX 2400 switch does not allow
stations to transfer calls to an attendant console.
1-10
Issue 2 December 1995
disconnect time is lower than the minimum time required by the
INTUITY System.
one second.