Setting Up A Ucd Overflow Group - NEC 2400 Integration Manual

Intuity integration with nec neax 2400 switch
Table of Contents

Advertisement

NEAX 2400 Switch Administration
5. In the second STN field, enter the second voice mail port station you need
to assign to the UCD group.
Using the 500, 501, 502, and 503 example, enter 501 as the second voice
mail port station.
6. Repeat Step 5 until you enter all voice mail port extensions in the UCD
group. The system continues to ask for voice mail port extensions until you
enter the enough stations to match the CNT field.
In the examples above, CNT was set to 4. Extensions 500, 501, 502, and
503 were assigned to the UCD group. 503 is the fourth and last extension.
7. After you enter the last extension for the UCD group, you see the message
WRT? on the screen. Enter Y to confirm and save the information you
entered.
8. Press
menu.

Setting Up a UCD Overflow Group

On the NEAX 2400 switch, you can create a maximum of 7 UCD groups with 20
station extensions in each UCD group. If all the extensions in a UCD group are
busy, calls do not automatically transfer to the next group. You must use the
UCD Overflow feature to link the groups together. By using the UCD Overflow
feature, an incoming call transfers from a busy UCD group to another UCD
group. If you plan to use an INTUITY System with more than 24 ports, you must
use the UCD overflow feature.
NOTE:
The NEAX 2400 switch must have software version 4200 or greater to
support UCD overflow. If the switch does not contain software version
4200 or greater, the SID only supports 20 voice mail extensions, the
maximum allowed in one UCD group.
Use the following instructions to administer UCD Overflow.
1. Use the instructions in the previous section, ""Assign Voice Mail
Extensions to a UCD Group"" to assign all voice mail ports to UCD groups.
For example, if you are setting up an INTUITY System with 24 ports, you
could set up 4 UCD groups with 6 ports in each group. Determine the
best method for your application.
2. After you create all necessary UCD groups and return to the Station Data
Command menu, enter 15 to select the Assignment of UCD Overflow
option.
7-8
Issue 2 December 1995
to exit the screen and return to the Station Data Commands
/

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 2400

Table of Contents