2.5.2 Ceiling Mounting

1.
2.
Issue 11 (2015-05-18)
NOTE
The AP5030DN and AP5130DN use a different type of sheet metal mounting bracket than other APs.
When installing an AP5030DN or AP5130DN, align the mounting screws at the rear of the AP with the
mounting holes on the sheet metal mounting bracket and then press the AP downwards to secure the AP
on the bracket.
Fix a locking clip at the rear of the AP with two M3x6 screws. The locking clip prevents
the AP hung on the mounting bracket from swaying.
NOTE
Only the AP6310SN-GN and AP7110 series require the locking clip during their installation.
1
1. M3x6 screw
Remove a ceiling tile, determine locations of mounting holes based on the distance between
two installation holes on the mounting bracket, use a hammer drill to drill holes on the
ceiling tile, and fix the mounting bracket to the ceiling tile.