Huawei AP3010DN-AGN Hardware Installation And Maintenance Manual page 53

Hide thumbs Also See for AP3010DN-AGN:
Table of Contents

Advertisement

Huawei AP3x10xN&5x10xN&5x30xN&6x10xN&7x10xN
Hardware Installation and Maintenance Guide
When you strip a power cable, do not damage the conductor of the cable.
Figure 5-12 Stripping a power cable (cord end terminal)
Table 5-3 Mapping between the cross-sectional area of the conductor and the value of L1
Cross-
Sectional Area
of Conductor
(mm
1 (0.002)
1.5 (0.002)
2.5 (0.004)
4 (0.006)
6 (0.009)
Step 2 Putting the cord end terminal onto the conductor, and ensure that the conductor is aligned with
the edge of the cord end terminal, as shown in
After the conductor is fed into the cord end terminal, the protruding part of the conductor must
not be longer than 1 mm (0.04 in.).
Issue 11 (2015-05-18)
NOTICE
Value of L1 (mm
(in.))
2
2
(in.
))
8 (0.31)
10 (0.39)
10 (0.39)
12 (0.47)
14 (0.55)
NOTICE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Cross-Sectional
Area of Conductor
2
2
(mm
(in.
))
10 (0.015)
16 (0.025)
25 (0.039)
35 (0.054)
50 (0.077)
Figure
5-13.
5 Appendix
Value of L1 (mm
(in.))
15 (0.59)
15 (0.59)
18 (0.71)
19 (0.75)
26 (1.02)
46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents