09.01
Example
7.5
PC MPI mode
Description
Requirements
Calling the OP 030
© Siemens AG, 2001. All rights reserved
SINUMERIK 840D/810D Configuring the OP 030 Operator Interface (FBO) – 09.01 Edition
Value dependent on data type
value
comment
Any comment up to the end of the line
#Separator format SyId Area Col Row BlockType NumCol Value
0 4 '130 65 1 1 16 1' "4"#P_C_Y_numGeoAxes
0 4 '130 65 2 1 16 1' "1"# " _numAuxAxes
0 4 '130 65 3 1 16 1' "4"# " _numMachAxes
0 4 '130 65 4 1 16 1' "4"# " _numSpindles
0 4 '130 33 3 1 127 1' "1"#B_S_opMode
The OP 030 software communicates with an NC or PLC in PC MPI
mode. The logical response corresponds to the real conditions of the
OP 030 hardware.
You must use a PG programming device or PC with an AT MPI card.
In file bt0.ini in \bin, change the entry
pc_test to pc_test = 0.
Notice
Please do not modify any other entries in this file or change the order of
the entries.
For more information see the previous section.
Change to the L:\bin directory.
Load the MPI drivers:
com030 tsr
The OP 030 software is started in PC MPI mode by entering
OP 030.
Development Kit (EU)
7 OP 030 Operation
EU/7-57